Services We Perform
| • Domestic & Commercial |
• RCD Faults |
| • Faults & Repairs |
• 3 Phase Commercial Circuit Faults |
| • Immersion Heaters |
• Commercial Lamp Replacements |
| • Fuse Boards |
• New Installations |
| • Flood Damage Repairs |
• Test and Inspection |
| • Fuses |
|
Types of Work Undertaken
Rewires
All full rewires will comply with the BS7671 regulations and include new wiring and fittings, new consumer unit including MCBs and RCD. All relevant bonding to BS7671 regulations. A full estimate will be supplied with full IEE certificate on completion.
Faults
Domestic and Commercial
- Faults/repairs
- Lights faults
- Sockets faults
- Immersion heaters
- Fuse board problems
- Low voltage lights fault
- Checks after flood
- Fuses blown – tripping
- RCD faults
- 3 phase commercial circuit faults
- Lamp replacement for offices and shops
Appliances Repaired include:
- Cookers
- Storage heaters
- Showers
New Installations:
- New light fittings
- Low voltage lighting
- New shower circuits
- New cooker circuits
- Outside lights/sockets
- Extra sockets
- Wiring outside sheds/workshops
- 3 phase circuits installed
- Fork lift truck charging circuits
- Kitchen rewires
- Modernise consumer units (to include RCD and MCBs)
- Update Earth Bonding
Test and Inspections
NICEIC Periodic Inspections
A full test on the supply of your home/business to BS7671 IEE Wiring Regulations including fuse board, earthing arrangements, wiring, fixtures and fittings (i.e. lights, sockets, switches). Installation methods, loose connections etc.
The following tests are carried out:
- Continuity of earth conductors
- Continuity of ring final conductors
- Polarity
- Installation resistance – to check for any arking or moisture between phase – phase earth
- Earth loop impedance – to verify path of earth
- RCD test to check tripping times and mA settings
The test involves testing circuits at the consumer unit and various points around the property and includes a visual inspection as well as an instrumental test.
The testers used are:
- Voltage tester to measure Volts
- Continuity tester to measure ohms
- Insulation resistance to measure Mohms
- Earth loop impendence tester to measure ohms
- RCD tester to measure mS
Also the supplies characteristics are tested to ensure a good earth and path of fault current is present. These tests are called Ze and PSC (Prospective Short Circuit).
The NICEIC inspector who carries out this test enrols to the NICEIC and his work is checked yearly by the NICEIC to ensure he works to the BS7671 IEE Regulations.
Homebuyers
This check is very useful when buying a house to check if it requires any updating or rewiring prior to purchase. A visual inspection to verify whether the property has current earthing arrangements present and cables are PVC (not rubber/lead), that the consumer units have RCD protection for ground floor sockets (to provide facility for outside use) and has correct overload protection for circuits (i.e. lights 6A not 40A.)
PAT (Portable Appliance Testing)
- specialist PAT testing carried out by qualified engineers
- state of the art calibrated test equipment
- stickers provided on each appliance and a schedule of appliances
tested, sent out on completion
- competitive rates, depending on amount of items
- schools; care homes; shops; cafes; restaurants; clubs; domestic
and commercial; DJ equipment
- CALL FOR A FREE ESTIMATE
Electrical Installation Certificates
This certificate is required by the supply service provider (i.e. London Electricity) when a property needs reconnection after any period of time. It checks supply and earth conductivity to ensure the supply is safe to connect to.
Emergency Lighting
Verification of cell operation on emergency lights required by BS7671, and function test for London electricians.
Fire Alarm Test
Function tests on panic buttons, smoke and fire detectors.
email us for information or a free quote for our services: info@milleniumelectrical.com
|